AFE5816ZAV
Texas Instruments
- Lifecycle
- Active
- Stock
- 2161 PCS
- Package
- NFBGA-289
- Series
- Acquisition de données - Analog Front End (AFE)
Cette comparaison détaillée des composants AFE5816ZAV et AFE5812ZCF vous offre un aperçu précieux de leurs spécifications et caractéristiques clés. Nous abordons en détail les facteurs importants, notamment la conformité RoHS, le statut REACH, la série, le mode de montage, le type de boîtier et d'autres caractéristiques pertinentes. La présentation côte à côte des différences simplifie la sélection des composants et vous permet de choisir plus facilement la meilleure option pour votre application spécifique.
Replacement verdict
The AFE5816ZAV and AFE5812ZCF are both 16-channel ultrasound analog front ends from Texas Instruments sharing the same TQFP-100 package and 5 V analog supply architecture, making them strong functional replacement candidates. However, the AFE5816ZAV offers a higher maximum sampling rate (65 MSPS versus 50 MSPS) and a different digital output interface, so system-level validation of clocking, output timing, and firmware configuration is required before substitution.
Texas Instruments
Texas Instruments
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AFE5816ZAV | AFE5812ZCF | Why it matters |
|---|---|---|---|
| Number of Channels | 16 | 8 | Channel count determines how many transducer elements can be processed simultaneously, directly affecting system density and imaging architecture. |
| Analog-to-Digital Converter Resolution | 14 bit | 12 bit | Higher ADC resolution provides greater dynamic range and finer signal detail, which impacts image quality and small-signal detection. |
| Maximum Sampling Rate | 65 MSPS | 50 MSPS | Sampling rate limits the maximum signal bandwidth and achievable axial resolution in ultrasound receive chains. |
| Package Type | NFBGA (ZAV) | NFBGA (ZCF) | Package footprint and pinout must match the PCB layout for a drop-in replacement; differing package codes indicate layout incompatibility. |
| Input Referred Noise | 0.8 nV/√Hz (typical) | 1.0 nV/√Hz (typical) | Lower input-referred noise improves sensitivity and penetration depth in ultrasound imaging front ends. |
| Total Power Consumption | Approximately 1.1 W (16 channels) | Approximately 0.6 W (8 channels) | Power budget affects thermal design and portability; per-channel power and total channel count both influence system power planning. |
| Time Gain Compensation Range | Up to 45 dB | Up to 40 dB | TGC range determines the ability to compensate for depth-dependent attenuation of returning echoes. |
| LNA Gain Range | Configurable (up to ~24 dB) | Configurable (up to ~24 dB) | Low-noise amplifier gain settings affect the noise figure and signal handling capability of the receive channel. |
| Continuous Wave (CW) Doppler Support | Supported | Supported | CW Doppler capability is required for blood flow velocity measurement; both devices support it, preserving this function. |
| Operating Temperature Range | -40°C to +85°C | -40°C to +85°C | Industrial temperature range ensures reliable operation across medical and industrial environments. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AFE5816ZAV | AFE5812ZCF |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Active |
| Number of Bits | 12, 14 | 12, 14 |
| Number of Channels | 16 | 8 |
| Power (Watts) | 94 mW | 180 mW |
| Voltage - Supply, Analog | 1.7V ~ 2V, 3V ~ 3.3V | 1.7V ~ 1.9V, 3.15V ~ 3.6V, 5V |
| Voltage - Supply, Digital | 1.15V ~ 1.25V, 1.7V ~ 1.9V | 1.7V ~ 1.9V |
| Mounting Type | Surface Mount | Surface Mount |
The AFE5816ZAV and AFE5812ZCF are fully integrated analog front-end (AFE) devices from Texas Instruments designed for ultrasound imaging systems. Each integrates a low-noise amplifier (LNA), voltage-controlled attenuator (VCA), programmable gain amplifier (PGA), and a 14-bit analog-to-digital converter (ADC) to process multiple ultrasound channels.
The AFE5816ZAV integrates 16 channels, while the AFE5812ZCF integrates 8 channels. This difference directly affects the number of transducer elements each device can support and the overall channel density of the ultrasound system design.
The AFE5816ZAV is supplied in a 289-ball NFBGA (ZAV) package, whereas the AFE5812ZCF is supplied in a 196-ball NFBGA (ZCF) package. The different ball counts and footprints mean the two devices are not drop-in replacements and require distinct PCB land patterns.
Yes. Both devices integrate a 14-bit ADC with a maximum sampling rate of 65 MSPS per channel, providing comparable digital output resolution and conversion speed for ultrasound signal processing.
No. Because the AFE5816ZAV uses a 289-ball NFBGA package and the AFE5812ZCF uses a 196-ball NFBGA package, they are not pin-to-pin compatible. A redesign of the PCB layout is required when migrating between the two devices.
Per-channel power consumption is comparable between the two devices, but total power differs because the AFE5816ZAV integrates 16 channels while the AFE5812ZCF integrates 8 channels. System-level power budgeting should account for the total channel count in each design.
Both devices target ultrasound imaging signal chains and share the same functional block architecture (LNA, VCA, PGA, 14-bit ADC). However, because of the differing channel counts and package footprints, they suit different system partitioning and cannot be interchanged without layout and channel-mapping changes.