AD7622BSTZ vs AD7623ASTZRL

Cette comparaison détaillée des composants AD7622BSTZ et AD7623ASTZRL vous offre un aperçu précieux de leurs spécifications et caractéristiques clés. Nous abordons en détail les facteurs importants, notamment la conformité RoHS, le statut REACH, la série, le mode de montage, le type de boîtier et d'autres caractéristiques pertinentes. La présentation côte à côte des différences simplifie la sélection des composants et vous permet de choisir plus facilement la meilleure option pour votre application spécifique.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD7622BSTZ and AD7623ASTZRL are both 16-bit, 1 MSPS PulSAR analog-to-digital converters from Analog Devices, sharing the same LQFP-48 package and core architecture. The AD7623ASTZRL offers a higher typical SNR and lower power consumption, making it a strong functional candidate for the AD7622BSTZ in most precision acquisition designs, provided the user validates the specific timing and interface requirements of the target application.

Resolution and Sample Rate High match
Package Type High match
Supply Voltage High match
Dynamic Performance Validation required

Parts at a glance

Part A

AD7622BSTZ

Analog Equipment GmbH.

Lifecycle
Active
Stock
5006 PCS
Package
LQFP-48
Series
Acquisition de données - Convertisseur analogique - numérique (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD7622BSTZ AD7623ASTZRL Why it matters
Resolution 16 bit 16 bit Both are 16-bit SAR ADCs, so nominal resolution is identical and not a differentiator for substitutability.
Sampling Rate 2 MSPS 1.33 MSPS The AD7622 offers a higher maximum throughput, which affects achievable data rate and timing budget in the application.
Input Type Differential Differential Both accept differential inputs, so the analog front-end topology can remain the same.
Supply Voltage (Analog) 5 V 5 V Identical analog supply requirements simplify power rail reuse between the two parts.
Interface SPI / Parallel SPI / Parallel Both support serial and parallel interfaces, allowing the same digital host connection to be reused.
Package 48-Lead LQFP 48-Lead LQFP Identical package and pinout enable drop-in board compatibility without layout changes.
Operating Temperature Range -40 to +85 °C -40 to +85 °C Matching temperature ranges ensure equivalent environmental robustness for the target application.
Power Consumption Higher (2 MSPS operation) Lower (1.33 MSPS operation) The faster part typically dissipates more power, which matters for thermal and energy-sensitive designs.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD7622BSTZ AD7623ASTZRL
Supplier - Analog Devices Inc.
Series PulSAR® PulSAR®
Part Status Active Obsolete
Number of Bits 16 16
Sampling Rate(Per Second) 2M 1.33M
Number of Inputs 1 1
Input Type Differential Differential
Data Interface SPI, Parallel, DSP SPI, Parallel, DSP
Configuration S/H-ADC S/H-ADC
Ratio - S / H: ADC 1:1 1:1
Number of A/D Converters 1 1
Architecture SAR SAR
Reference Type External, Internal External, Internal
Voltage - Supply, Analog 2.37V ~ 2.63V 2.37V ~ 2.63V
Voltage - Supply, Digital 2.37V ~ 2.63V 2.37V ~ 2.63V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C

Frequently asked questions

What are the key differences between the AD7622BSTZ and AD7623ASTZRL?

The AD7622BSTZ is a 16-bit, 2 MSPS PulSAR differential ADC in a 48-lead LQFP package, while the AD7623ASTZRL is a 16-bit, 1.33 MSPS PulSAR differential ADC in a 48-lead LQFP package. The primary differences are throughput rate (2 MSPS vs 1.33 MSPS) and the corresponding power consumption and timing specifications.

Are the AD7622BSTZ and AD7623ASTZRL pin-compatible?

Both devices are offered in the same 48-lead LQFP package and share the same pinout for the PulSAR family, allowing board-level compatibility. However, designers must verify timing and throughput differences before substituting one for the other in an existing design.

What is the resolution and architecture of these ADCs?

Both the AD7622BSTZ and AD7623ASTZRL are 16-bit successive-approximation register (SAR) analog-to-digital converters using the PulSAR architecture, providing no pipeline delay and accurate DC linearity performance.

What are the maximum sampling rates of the AD7622BSTZ and AD7623ASTZRL?

The AD7622BSTZ supports a maximum throughput of 2 MSPS, while the AD7623ASTZRL supports a maximum throughput of 1.33 MSPS. Both rates apply to the fully differential input configuration.

Do both devices support the same analog input configuration?

Yes, both the AD7622BSTZ and AD7623ASTZRL feature fully differential analog inputs with a specified input voltage range of ±VREF, supporting differential signal chains commonly used in medical imaging, data acquisition, and instrumentation applications.

What is the difference in power consumption between the two parts?

The AD7622BSTZ, operating at 2 MSPS, consumes approximately 90 mW typical at 5 V supply. The AD7623ASTZRL, operating at 1.33 MSPS, consumes approximately 65 mW typical. Lower throughput in the AD7623ASTZRL results in reduced power dissipation.

What digital interface do the AD7622BSTZ and AD7623ASTZRL use?

Both devices provide a parallel digital interface with a flexible host interface, supporting both parallel and serial readback modes. The interface is compatible with 2.5 V, 3 V, and 5 V logic supplies, allowing direct connection to a variety of digital hosts.

Can the AD7623ASTZRL be used as a drop-in replacement for the AD7622BSTZ?

Because both parts share the same package and pinout, the AD7623ASTZRL can be placed on a board designed for the AD7622BSTZ. However, the lower maximum throughput (1.33 MSPS vs 2 MSPS) and different timing specifications must be validated against the system requirements before substitution.