ACPL-C87B-000E vs ACPL-C87A-500E

Cette comparaison détaillée des composants ACPL-C87B-000E et ACPL-C87A-500E vous offre un aperçu précieux de leurs spécifications et caractéristiques clés. Nous abordons en détail les facteurs importants, notamment la conformité RoHS, le statut REACH, la série, le mode de montage, le type de boîtier et d'autres caractéristiques pertinentes. La présentation côte à côte des différences simplifie la sélection des composants et vous permet de choisir plus facilement la meilleure option pour votre application spécifique.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ACPL-C87B-000E is a viable functional replacement candidate for the ACPL-C87A-500E, sharing the same isolation amplifier architecture, input voltage range, and package footprint. Both devices are pin-compatible and differ primarily in gain tolerance and packaging format, making the ACPL-C87B-000E suitable for designs where tighter gain accuracy is beneficial and tube packaging is acceptable.

Package Type High match
Input Voltage Range High match
Gain Tolerance Validation required
Packaging Format Validation required

Parts at a glance

Part A

ACPL-C87B-000E

Broadcom Ltd

Lifecycle
Active
Stock
7760 PCS
Package
SSO-8
Series
Amplificateurs linéaires - instruments, amplificateurs opérationnels, amplificateurs tampons
Part B

ACPL-C87A-500E

Broadcom Ltd

Lifecycle
Active
Stock
7176 PCS
Package
SSO-8
Series
Amplificateurs linéaires - instruments, amplificateurs opérationnels, amplificateurs tampons

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ACPL-C87A-500E ACPL-C87B-000E Why it matters
Manufacturer Part Number ACPL-C87A-500E ACPL-C87B-000E Distinct orderable part numbers indicate different gain/accuracy grades and packaging options, so they are not drop-in identical.
Gain Tolerance ±1% ±0.5% Tighter gain tolerance improves measurement accuracy in isolated voltage sensing applications.
Gain Error Grade A grade B grade The grade determines the specified accuracy class and directly affects system calibration requirements.
Packaging / Option Suffix 500E tape and reel 000E tube Different packaging affects automated assembly compatibility and handling for production lines.
Isolation Voltage 5000 Vrms 5000 Vrms Isolation rating is critical for safety and compliance in high-voltage measurement systems.
Input Type Isolated analog voltage input Isolated analog voltage input Matching input type ensures the device interfaces with the same sensing front end.
Output Type Differential analog output Differential analog output Identical output topology allows reuse of the same downstream ADC or signal conditioning circuit.
Supply Voltage 5 V 5 V Same supply voltage means no power rail redesign is needed when substituting parts.
Operating Temperature Range -40°C to +105°C -40°C to +105°C Equivalent temperature range ensures both parts can be used in the same industrial environments.
Package Type SO-8 (stretched) SO-8 (stretched) Same package footprint allows direct PCB placement without layout changes.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ACPL-C87B-000E ACPL-C87A-500E
Part Status Active Active
Amplifier Type Isolation Isolation
Number of Circuits 1 1
Output Type Differential Differential
-3 dB Bandwidth 100 kHz 100 kHz
Current - Input Bias 1.5 nA 1.5 nA
Voltage - Input Offset 300 µV 300 µV
Supply Current 10.5mA 10.5mA
Current - Output / Channel 30 mA 30 mA
Voltage - Supply Span(Min) 3 V 3 V
Voltage - Supply Span(Max) 5.5 V 5.5 V
Operating Temperature -40°C ~ 105°C -40°C ~ 105°C
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the ACPL-C87A-500E and ACPL-C87B-000E?

The ACPL-C87A-500E and ACPL-C87B-000E are optically isolated voltage sensors from Broadcom (formerly Avago Technologies). They are designed for isolated voltage sensing in applications such as motor drives, inverters, and industrial control systems, providing galvanic isolation between the high-voltage and low-voltage sides.

What is the difference between the ACPL-C87A-500E and ACPL-C87B-000E?

The primary difference is the gain tolerance and packaging option. The ACPL-C87A-500E offers a tighter gain tolerance of ±1%, while the ACPL-C87B-000E has a gain tolerance of ±3%. Additionally, the ACPL-C87A-500E is supplied in tape and reel packaging (suffix 500E), whereas the ACPL-C87B-000E is supplied in tube packaging (suffix 000E).

Are the ACPL-C87A-500E and ACPL-C87B-000E pin-compatible?

Yes, both devices are pin-compatible. They share the same package type (SO-8 stretched) and pinout, allowing them to be used interchangeably on the same PCB footprint, provided the gain tolerance and packaging requirements are acceptable for the application.

What is the isolation voltage rating for these components?

Both the ACPL-C87A-500E and ACPL-C87B-000E have a rated isolation voltage of 5000 Vrms for 1 minute per UL 1577. They also offer a working voltage of 1414 Vpeak per IEC/EN/DIN EN 60747-5-5, making them suitable for high-voltage isolation applications.

What is the input voltage range of the ACPL-C87A-500E and ACPL-C87B-000E?

Both devices have an input voltage range of ±200 mV, with a nominal input voltage of 200 mV. They are designed to sense small differential voltages across a shunt resistor in isolated voltage sensing applications.

Can the ACPL-C87A-500E and ACPL-C87B-000E be used in safety-critical applications?

Yes, both devices are certified to relevant safety standards, including UL 1577, CSA, and IEC/EN/DIN EN 60747-5-5. However, the specific safety requirements of the end application must be evaluated to ensure compliance. The ACPL-C87A-500E with tighter gain tolerance may be preferred for applications requiring higher accuracy.

What is the operating temperature range for these components?

Both the ACPL-C87A-500E and ACPL-C87B-000E are specified for an operating temperature range of -40°C to +105°C, making them suitable for industrial and automotive environments.

Which part should be selected for a new design, ACPL-C87A-500E or ACPL-C87B-000E?

The selection depends on the required gain accuracy and production packaging. Choose the ACPL-C87A-500E for applications needing tighter gain tolerance (±1%) and tape-and-reel packaging for automated assembly. Choose the ACPL-C87B-000E for applications where a ±3% gain tolerance is acceptable and tube packaging is preferred. Both offer identical isolation and input voltage specifications.