ACPL-C79B-000E vs ACPL-C784-500E

Cette comparaison détaillée des composants ACPL-C79B-000E et ACPL-C784-500E vous offre un aperçu précieux de leurs spécifications et caractéristiques clés. Nous abordons en détail les facteurs importants, notamment la conformité RoHS, le statut REACH, la série, le mode de montage, le type de boîtier et d'autres caractéristiques pertinentes. La présentation côte à côte des différences simplifie la sélection des composants et vous permet de choisir plus facilement la meilleure option pour votre application spécifique.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ACPL-C79B-000E is a viable functional replacement candidate for the ACPL-C784-500E, sharing the same isolation amplifier architecture, input range, and output configuration. Designers should validate the tighter gain tolerance and reduced operating temperature range against their specific application requirements before committing to a drop-in substitution.

Output Type High match
Input Signal Range High match
Gain Tolerance Validation required
Operating Temperature Range Validation required

Parts at a glance

Part A

ACPL-C79B-000E

Broadcom Ltd

Lifecycle
Active
Stock
5529 PCS
Package
SSO-8
Series
Amplificateurs linéaires - instruments, amplificateurs opérationnels, amplificateurs tampons
Part B

ACPL-C784-500E

Broadcom Ltd

Lifecycle
Active
Stock
6380 PCS
Package
SSO-8
Series
Amplificateurs linéaires - instruments, amplificateurs opérationnels, amplificateurs tampons

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ACPL-C784-500E ACPL-C79B-000E Why it matters
Manufacturer Broadcom Broadcom Confirms both parts come from the same supplier, simplifying sourcing and qualification.
Amplifier Type Isolation Amplifier Isolation Amplifier Both are isolation amplifiers, so they serve the same core signal-conditioning function.
Input Offset Voltage (Max) ±0.3 mV ±0.3 mV Low offset voltage improves measurement accuracy in current-sensing applications.
Gain Tolerance ±1% ±1% Tight gain tolerance ensures consistent signal scaling between parts.
Isolation Voltage (VISO) 5000 Vrms 5000 Vrms High isolation voltage is critical for safety and noise immunity in high-voltage systems.
Bandwidth 100 kHz 100 kHz Bandwidth determines the maximum signal frequency the amplifier can accurately process.
Supply Voltage Range 4.5 V to 5.5 V 4.5 V to 5.5 V Compatible supply range allows direct replacement without power rail redesign.
Operating Temperature Range -40°C to +105°C -40°C to +105°C Industrial temperature range ensures reliable operation in harsh environments.
Package / Mounting Surface Mount (SO-8) Through-Hole (DIP-8) Different mounting styles affect PCB layout and assembly compatibility.
Packaging Option Tape & Reel Tube Packaging affects handling and compatibility with automated assembly lines.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ACPL-C79B-000E ACPL-C784-500E
Part Status Active Active
Amplifier Type Isolation Isolation
Number of Circuits 1 1
Output Type Differential Differential
-3 dB Bandwidth 200 kHz 100 kHz
Current - Input Bias 100 nA -
Voltage - Input Offset 600 µV 300 µV
Supply Current 13mA 11mA
Current - Output / Channel 11 mA 18.6 mA
Voltage - Supply Span(Min) 4.5 V 4.5 V
Voltage - Supply Span(Max) 5.5 V 5.5 V
Operating Temperature -40°C ~ 105°C -40°C ~ 85°C
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the primary differences between the ACPL-C784-500E and the ACPL-C79B-000E?

The ACPL-C784-500E is a ±0.5% tolerance isolated amplifier with a ±50 mV input range, while the ACPL-C79B-000E is a ±0.5% tolerance isolated amplifier with a ±200 mV input range. Both are optically isolated amplifiers in a 5-pin SO-8 package, but they differ in input voltage range, gain, and specified operating temperature range.

Are the ACPL-C784-500E and ACPL-C79B-000E pin-compatible?

Yes. Both devices are offered in the same 5-pin surface-mount SO-8 package with identical pin functions: VDD1, VIN+, VIN-, GND1, VDD2, VOUT+, VOUT-, and GND2. This allows for a common PCB footprint, but electrical differences must be validated before substitution.

What is the input voltage range of each device?

The ACPL-C784-500E has a nominal input voltage range of ±50 mV. The ACPL-C79B-000E has a nominal input voltage range of ±200 mV. These ranges determine the maximum differential signal that can be accurately amplified without clipping.

What are the gain and gain tolerance specifications for these isolated amplifiers?

The ACPL-C784-500E provides a fixed gain of 8.2 V/V with a tolerance of ±0.5%. The ACPL-C79B-000E provides a fixed gain of 8.2 V/V with a tolerance of ±0.5%. Despite the different input ranges, both devices have the same nominal gain, resulting in different output voltage swings for a given input.

What is the specified operating temperature range for each part?

The ACPL-C784-500E is specified for operation from -40°C to +105°C. The ACPL-C79B-000E is specified for operation from -40°C to +105°C. Both devices share the same industrial temperature range.

What isolation voltage and safety certifications apply to these components?

Both the ACPL-C784-500E and ACPL-C79B-000E are rated for 5 kV rms isolation for 1 minute per UL 1577. They also carry IEC/EN/DIN EN 60747-5-5 approval for reinforced insulation with a working voltage of 1,140 V peak. These ratings are identical for both parts.

Can the ACPL-C784-500E and ACPL-C79B-000E be used interchangeably in a design?

They are not directly interchangeable without circuit redesign. The ACPL-C784-500E accepts a ±50 mV input, while the ACPL-C79B-000E accepts a ±200 mV input. Using one in place of the other will result in a different output voltage for the same input signal, potentially causing saturation or loss of resolution. The surrounding signal conditioning and shunt resistor values must be recalculated.

What are the typical applications for each device?

The ACPL-C784-500E is typically used for low-level signal isolation such as shunt-based current sensing in motor drives and power inverters where the shunt voltage is small. The ACPL-C79B-000E is used for higher-level signal isolation, such as DC bus voltage monitoring or current sensing with larger shunt voltages, where a wider input range is beneficial.